This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
On Sun, 25 Apr 1999, Dan Vietor wrote: > > >Has anyone else had a problem getting RCM data? The last RCM summary > > >that we received was 23/21Z. Everything else seems to be coming > > >through. > > RCM products are coming across on NOAAPORT (here at Unisys) but I'm not > seeing them at Purdue (IDD). Maybe Robb's change for the NIDS data > filtered out the RCM products as well. > > RCM products come in on SDUS40, SDUS41, SDUS42, SDUS43, SDUS44, SDUS45, > SDXX99, SDUS99. > Hiya, oops, the filter was too stringent to let the above products into the IDD. It must be a weekend brain lapse on RE. Here's the new filter that lets the SD.... products into the IDD. "(^[A-RT-Z])|(^S[^D])|(SD..[0-8])|SD..(90|91|92|93|94|95|96|98|99)" The filter has been installed on thelma so only SSEC and NCAR need to apply the filter. No other sites need to install the filter. Robb... =============================================================================== Robb Kambic Unidata Program Center Software Engineer III Univ. Corp for Atmospheric Research address@hidden WWW: http://www.unidata.ucar.edu/ ===============================================================================