This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Kevin,
I just received the following from our system administrator, Mike
Schmidt.
--Steve
------- Forwarded Message
From: "Mike Schmidt" <address@hidden>
Date: Wed, 29 Jul 1998 16:21:21 -0600
In-Reply-To: Steve Emmerson <address@hidden>
"HP problem" (Jul 29, 3:52pm)
To: Steve Emmerson <address@hidden>
Subject: Re: HP problem
On Jul 29, 3:52pm, Steve Emmerson wrote:
> Subject: HP problem
>
> ld: (Warning) At least one PA 2.0 object file (NetCDF.o) was detected. The
linked output may not run on a PA 1.x system.
Indeed, not a problem but the makefile could use +v[no]compatwarnings
option for builds on HPUX 10.x or later systems so customers don't worry
about this sort of thing...
> ld: Invalid loader fixup for symbol "$00000064".
Based on the information I have, it seems that a recent dld.sl patch
for HPUX 10.20 should get rid of the error. Install the latest patch;
ftp://i3107ffs.external.hp.com/hp-ux_patches/s700_800/10.X/PHSS_15391
and let me know if the error persists.
mike
------- End of Forwarded Message