This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Brad, I modified pqing(1) along the lines of your patch. They'll be in the next release. > LDM Support: > > We are running ldm version 6.12.14. > > We use pqing to insert WMO bulletins into the ldm queue via a socket > connection to our noaaport ingestor. I'm seeing the following messages > in the pqing log file (for example) ... > > NOTE: YAUS21 KWNR 151826 : no end of product > ERROR: Not a WMO GRIB format message. > > This is one of the new GRIB2 formatted bulletins. This message appears > in the log for every new GRIB2 bulletin. > > Several months ago, I instrumented the pqing code (on the version I had > at the time) and determined that the code that calculates the bulletin > length was not correct for the GRIB2 bulletins. I sent this information > to Unidata in an e-mail. > > Gribinsert is not the best option for us. We would like to use pqing, > if at all possible. > > Thank you, > > Brad Regards, Steve Emmerson Ticket Details =================== Ticket ID: KRB-795296 Department: Support LDM Priority: Normal Status: Closed