This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
John,
I think the system clock on adiabat.rwic.und.edu is way off. A log
entry on our end
Dec 21 06:38:37 uni7 adiabat.rwic.und.edu(feed)[21535] NOTE: Starting
Up(6.6.5/6): 20071221123703.124 TS_ENDT {{NEXRAD2, ".*"}},
SIG=f4b8fe8602b3e45183f549f33befac65, Primary
shows Adiabat connecting at 2007-12-21 06:38:37 UTC but requesting
data-products from 2007-12-21 12:37:03.124 UTC (i.e., in the
future). It took a while for time to catch-up to your request.
Take a look at the system clock. If it's off, then reset it and
use the "ntpd" daemon to keep it accurate. More information can
be found at
<http://www.unidata.ucar.edu/software/ldm/ldm-current/basics/platform.html>
Regards,
Steve Emmerson