This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Hi Waldenio! >Date: Thu, 17 Feb 2005 08:38:39 -0700 >From: Unidata Support <address@hidden> >Organization: INPE/CPTEC >To: address@hidden >Subject: 20050217: LDM and Firewall The above message contained the following: > During the works with the installations of new LDM machines, > a doubth arise: Ok, to relay data to another site, I need 388 port > free in-out (both directions) in the firewall. That's correct. > But in machines that only get data from another IDD partner (no relay), > I need only the firewall free to "in" at 388 port, while the > "out" can remain closed ? Your "in" and "out" seem reversed. Let computer A send data-products to computer B, then any firewall between A and B must allow packets to go from any port on B to port 388 on A. The firewalls must also allow packets to go from port 388 on A to the port on B that was used to establish the TCP connection. OK? Regards, Steve Emmerson