[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: 20011008: IDD latencies at PSU (cont.)



"Arthur A. Person" wrote:
> 
> On Wed, 17 Oct 2001, Anne Wilson wrote:
> 
> > "Arthur A. Person" wrote:
> > >
> > >
> > > Last night, had:
> > >
> > >           nutone->DDPLUS|IDS|HDS  (worked)
> > >           motherlode->NMC2|SPARE  (worked)
> > >
> > > This AM:
> > >
> > >          nutone->NMC2|SPARE   (but didn't get any data)
> > >          motherlode->DDPLUS|IDS|HDS   (worked)
> > >
> > > then, this AM:
> > >
> > >          motherlode->DDPLUS|IDS|HDS  (worked)
> > >          motherlode->NMC2|SPARE  (didn't appear to work)
> > >
> > > then,
> > >          nutone->DDPLUS|IDS|HDS (worked)
> > >          motherlode->NMC2|SPARE (worked)
> > >
> > > Maybe motherlode was just pokey starting up the NMC2 stuff...?  However,
> > > the last configuration above started immediately.  I don't recall how long
> > > I waited for the 3rd configuration above, but it must have been several
> > > minutes.  All 4 configurations above used two request lines.
> > >
> > >                                  Art.
> >
> > Thanks, Art.  At this point I'm going to assume configuration 3 was
> > indeed working properly, or at least wait until the problem appears
> > again.
> >
> > Are things still looking timely?
> 
> I've been running DDPLUS|IDS|HDS and NMC2|SPARE since this morning.  A
> quick check this afternoon showed the DDPLUS stuff running about 15
> minutes behind.  While this works, it's still not "normal".  I didn't do a
> comparison with notifyme from motherlode, but I assumed the DDPLUS stuff
> should have been on time.  I *did* do a comparison of NMC2 stuff with a
> notifyme from motherlode for NMC2 and in a couple of spot checks, saw that
> ldm.meteo.psu.edu was running from 7 to 15 minutes behind motherlode.  I
> will continue monitoring.  It may turn out that the hardware fix solved a
> lot of the problem, but maybe not all.  We'll see.
> 
> BTW, what's NMC3?
> 
>                                      Art.
> 

NMC3 is FNEXRAD, the floater NEXRAD feed.  It's very small.

Btw, a big change finally occurred today regarding the NMC2 feed - the
NWS is finally using Abilene to transmit the data to motherlode.  Before
it was severely constrained by a T1 line.  Right now that feed is only 3
minutes behind on motherlode - that's pretty good compared to the past.

And, yes, HDS is timely now on motherlode, as is IDS|DDPLUS.  

Is your SSEC feed and OU feed timely?  If so, I'm wondering if there's
some filtering going on.

Anne
-- 
***************************************************
Anne Wilson                     UCAR Unidata Program            
address@hidden                 P.O. Box 3000
                                  Boulder, CO  80307
----------------------------------------------------
Unidata WWW server       http://www.unidata.ucar.edu/
****************************************************