This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
> Bill, > > Get the IDV from the nightly builds (tomorrow). > > You can now specify the date format in the time series. > > Right click on the chart --> properties. In there, you should be able to set > the date format. > > Test it out for us ;-) > > -Julien > > > > Yuan > > > > > > I guess I did not explain my issues adequately. Please see the comments > > > I've inserted below. Thanks. > > > > > > Bill > > > > > > On 2/3/2011 12:51 PM, Unidata IDV Support wrote: > > > >>>> Full Name: bill fingerhut > > > >>>> Email Address: address@hidden > > > >>>> Organization: lyndon state college retired > > > >>>> Package Version: 2.9u2 build date:2010-12-03 08:14 UTC > > > >>>> Operating System: Windows XP > > > >>>> Hardware: Java: home: C:\Program Files\IDV_2.9u2\jre version: > > > >>>> 1.6.0_20 j3d:1.5.2 fcs (build4) > > > >>>> Description of problem: > > > >>>> > > > >>>> I am currently looking at 2 height-time displays and a data > > > >>>> probe/time > > > >>>> series. I believe everything is displayed according to the > > > >>>> documentation; > > > >>>> however, I would like to suggest a couple of possible improvements. > > > >>>> > > > >>>> First, the 2 height-time displays share the same geographic point > > > >>>> (lat,lon). I don't see how to make the probe time series share this > > > >>>> location. Is it now possible ? > > > >> Hi Bill, > > > >> The sharing of the geo location of two probe point is possible in the > > > >> IDV, you need to turn the share in the display control panel. Edit> > > > >> Sharing> Sharing On. > > > > > > This was already done, and it does not work as we expect. The 2 > > > height-time > > > displays share a point, but the probe time series does not. All 3 are > > > supposed > > > to be sharing the location point. > > > > Bill, > > It is my fault, I didn't read your report carefully. > > The time/height is a 3D probe and the time series is a 2D probe, to share > > the geo location of these two different spatial probe point may be > > complicated. I need more time to think about it. > > > > > > >>>> Second, the probe in the probe time series is easily customized via a > > > >>>> menu. I.e., the color and size can easily be changed. I don't see the > > > >>>> same capability with the height-time display. The color can be > > > >>>> changed > > > >>>> by changing the selector color, but I don't see how to make the size > > > >>>> of > > > >>>> the probe different. Can this be done ? > > > >> No, the size of the probe can not be changed. > > > > Bill, > > > > > > > > Sorry for this wrong information, the probe size can be changed. In the > > > > display control of the probe, Edit> Properties> Probe, you can change > > > > the size and shape, or you can do View> Probe>Size> Increase. > > > > > > I am aware of this. As I mentioned above, I see how to change the size > > > of the > > > probe in the probe time series display. I do not see how to change the > > > size > > > of the probe in the height-time display. There is no probe tab in this > > > control > > > as there is in the other type of display control. > > > > > I think we can add this feature to increase the size of time/height probe. > > > > Yuan Hi Bill, This feature are also available now, together with the date format improvement. It is in the display control window, under View > Probe > Size ..., you can also change the shape, reset the probe position. But your first suggestion of probe sharing between time series and the time/height will cause some unexpected side effect and need more consideration. Yuan > > > > > > > > Yuan > > > >>>> Third, the time labels in the probe/time series are quite long - > > > >>>> they take > > > >>>> a lot of space, which reduces the number of time labels possible. The > > > >>>> time format looks like the default in user preferences? Could we use > > > >>>> the same time format used in the height-time display (day/hour)? I > > > >>>> think > > > >>>> this would help the appearance quite a bit. > > > >>>> > > > >> This feature needs to be added, I will put it in the todo list. > > > >> > > > >> > > > >> Yuan > > > >>>> Just trying to help ! > > > >>> Hi Bill, > > > >>> Many Thanks for these improvement suggestions, I will check the > > > >>> source code after AMS to see how much work will involved to make > > > >>> these improvements. > > > >>> > > > >>> Yuan > > > >>>> > > > > > > > > Ticket Details > > > > =================== > > > > Ticket ID: BER-596188 > > > > Department: Support IDV > > > > Priority: Normal > > > > Status: Open > > > > > > > > > > > > > > > > > -- > > > The Fingerhuts > > > Saint Johnsbury, Vt, 05819 > > > > > > email: address@hidden > > > > > > > > > Ticket Details =================== Ticket ID: BER-596188 Department: Support IDV Priority: Normal Status: Open