This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Alex, > > Request SPARE "cptec\.01" mopora.cptec.inpe.br Primary > > Request SPARE "cptec\.02" mopora.cptec.inpe.br Primary > > Request SPARE "cptec\.03" mopora.cptec.inpe.br Primary > > Request SPARE "cptec\.04" mopora.cptec.inpe.br Primary > > Request SPARE "cptec\.05" mopora.cptec.inpe.br Primary > > Request SPARE "cptec\.06" mopora.cptec.inpe.br Primary > > Request SPARE "cptec\.07" mopora.cptec.inpe.br Primary > > Request SPARE "cptec\.AV" mopora.cptec.inpe.br Primary Just for your information, the "Primary" and "Alternate" modifiers are no longer used in LDM 6.4 -- so you might delete them to avoid confusion. For a given feedtype and pattern, the first REQUEST entry in the configuration-file will be the initial primary one, and all others will be in alternate mode. The primary-mode host will automatically change, however, depending on the network. Regards, Steve Emmerson Ticket Details =================== Ticket ID: DTM-735032 Department: Support IDD TIGGE Priority: Normal Status: Closed