This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.


  • Subject: [AWIPS #UXT-928462]: Surface Ob question
  • Date: Mon, 29 Jun 2020 11:27:08 -0500

Hi Peter,

Can you send me your pqact.conf file? LDM matches via the feedtype and file 
name, which by default is:

IDS|DDPLUS      ^(S[AP].{4}) (.{4}) (..)(..)(..)
        FILE    -overwrite -close -edex 
/awips2/data_store/metar/\1_\2_\3\4\5_(seq)

However your pqinsert command is using a different filename and you are not 
setting the feedtype (which by default is "EXP"). While you are inserting the 
file into your ldm queue successfully, it doesn't match any of the patterns in 
your pqact.conf file, so it's not getting pushed to EDEX. You can update the 
pattern and feedtype, restart LDM and should see: 

1. The file being stored in /awips2/data_store/metar/
2. The file in the 



Thanks,

Tiffany Meyer
AWIPS Lead Software Engineer
UCAR-Unidata

Ticket Details
===================
Ticket ID: UXT-928462
Department: Support AWIPS
Priority: Normal
Status: Open
===================
NOTE: All email exchanges with Unidata User Support are recorded in the Unidata 
inquiry tracking system and then made publicly available through the web.  If 
you do not want to have your interactions made available in this way, you must 
let us know in each email you send to us.