This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
This is new to me. From what I can find online this can happen after adding CPUs to a machine, and I remember you saying this machine was recently modified? In any case, you can try to remove the sa files being reported, and everything should be good. From http://serverfault.com/a/654366 "I have found that this happens when adding/removing (v)CPUs. Doing that probably adds/removes columns in the data file format or something. Removing the "invalid" saXX files and simply running sar caused it to regenerate and start collecting data again." To reply to your previous email, yes when 16.1.4 is released it will be an update to both EDEX and CAVE. > Not sure what to make of the errors below, but I installed > these packages on 30 March: > > > awips2-python-pint-0.7.2-1.x86_64 Wed 30 Mar 2016 12:03:34 PM > EDT > > awips2-python-metpy-0.3.0-2.x86_64 Wed 30 Mar 2016 12:03:34 PM > EDT Ticket Details =================== Ticket ID: UZJ-823843 Department: Support AWIPS Priority: Normal Status: Open