This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Good morning! I haven't been able to reproduce your problem yet, so I wanted to check a couple of things: 1. After changing your threddsConfig.xml did you restart thredds? This is necessary to reload config changes. 2. What version of thredds are you running? Best, Tara ================================================================ We're having trouble with the "get ascii" and "get binary" options. Get binary just gives a black screen and Get ascii gives this: Error { code = 403; message = "839.154952 Mbytes, max=50.0"; }; I configured the following in threddsConfig.xml but it doesn't see to have an effect: <Opendap> <ascLimit>999</ascLimit> <binLimit>999</binLimit> <serverVersion>opendap/3.7</serverVersion> </Opendap> Thanks! Ticket Details =================== Ticket ID: HTS-627432 Department: Support THREDDS Priority: Normal Status: Open =================== NOTE: All email exchanges with Unidata User Support are recorded in the Unidata inquiry tracking system and then made publicly available through the web. If you do not want to have your interactions made available in this way, you must let us know in each email you send to us.