Hi Carol,
re:
> As of 18:19 UTC today (Dec. 4th) we stopped receiving CONUS,
> Mesoscale-1, and Mesoscale-2 data. We are still currently getting
> FullDisk and GLM data.
>
> Are you seeing any outages in your GOES-16 feed? Any other ideas why
> this might be happening?
GOES-16 ABI was put in mode 4 scanning at approximately 18 UTC today. Mode 4 is
characterized by:
- full disk scans every 5 minutes
- no CONUS scans
- no Mesoscale scans
All non-ABI products (e.g., GLM) are unaffected by ABI scanning mode
changes.
Cheers,
Tom
--
****************************************************************************
Unidata User Support UCAR Unidata Program
(303) 497-8642 P.O. Box 3000
address@hidden Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage http://www.unidata.ucar.edu
****************************************************************************