Hi Mike,
Good news (for me, at least): I found and fixed a bug in the SCMI calibration
routine that I wrote. I also made small modifications to SSEC core routines
that were needed for full listings using IMGPROBE (mcgetscantime.for) and to
implement a fix that was made at SSEC but has not been released yet
(abincalb.inc).
The change in the SCMI calibration routine corrects a BONEHEAD mistake that
I made in a section that is only exercised when an SCMI image has been
IMGCOPYed to an AREA dataset and then interrogated by IMGPROBE.
I have done some simple tests of IMGCOPYing NPGOESR full disk images to a local
AREA dataset (MYDATA/IMAGES); IMGDISPed the original and copy into succeeding
frames using the exact same load; drawn maps over both; and IMGPROBEd both
at identical locations to make sure that the values I get in the original
and copy are the same.
I cut a new McIDAS-X distribution, v2017a, and put it out in the Downloads
area of our web site. I have also created an update file, mcupdate.tar.gz,
that can be used to update an existing v2017 installation by:
<as 'mcidas>
cd ~mcidas/mcidas2017/update
-- download mcupdate.tar.gz
-- download mcupdate
-- make sure that mcupdate is executable
./mcupdate
cd ../src
make && make install
The full distribution tar file, mcidasx2017.tar.gz, contains all of the
updated code, so you can also do:
<as 'mcidas'>
cd mcidas2017/src
make clobber
cd ~mcidas
-- download mcidasx2017.tar.gz
./mcunpack
cd mcidas2017/src
make && make install
Please let me know the results you see after upgrading...
Cheers,
Tom
--
****************************************************************************
Unidata User Support UCAR Unidata Program
(303) 497-8642 P.O. Box 3000
address@hidden Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage http://www.unidata.ucar.edu
****************************************************************************
Ticket Details
===================
Ticket ID: JGN-249914
Department: Support McIDAS
Priority: Normal
Status: Closed
===================
NOTE: All email exchanges with Unidata User Support are recorded in the Unidata
inquiry tracking system and then made publicly available through the web. If
you do not want to have your interactions made available in this way, you must
let us know in each email you send to us.