This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Hi Jim, et. al,
I uploaded 5 files to the pub/incoming directory on the SSEC FTP
server, ftp.ssec.wisc.edu that incorporate changes to the NEXRAD
Level III server to support the Base Spectrum Width (TS0) products
that Bob and Joleen want/are trying to use:
nexrutil.c - code additions
nexradir.cp - code additions
nexraget.cpa - code additions
kbxnexr.dlm - documentation additions
SATBAND - addition of definition of bands 18 (Melting Layer) and 19
(Base Spectrum Width)
Important Note:
- the additions I made to SATBAND need to be merged into what is undoubtedly
a new version of SATBAND contained in SSEC McIDAS-X v2015.1
I did not do the merge since I did not grab the v2015.1 version of SATBAND.
Bob and/or Joleen:
Please try out the updated server for TDWR TR0, TV0 and TS0 products when
you get a chance ** after ** Jim has had time to incorporate the new code
into the v2015.1 installation on rci.ssec.wisc.edu. As always, please let
me know the results of your testing.
Cheers,
Tom
--
****************************************************************************