This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Hi Bob, re: > Thanks for the clarification. I got confused on whose court this was in > after Bob R mentioned that he wasn't seeing valid IMGPROBE values with > the TV0 data using SSEC McIDAS, but it was working for you with Unidata > McIDAS, so that's why I jumped in on the conversation. Yup, that is what I figured; I would have done the same thing. re: > I'll hold off on > looking any further into this until I hear back about things working for > Joleen and Bob R on the rci.ssec.wisc.edu server. OK. Jim said that he put in a request to TC to configure the ADDE remote server setup on rci to use his early SSEC McIDAS-X v2015.1 distribution that he updated with the NEXRAD Level III/TDWR server code modes that I gave him last week. I just checked the status of this by displaying and interrogating one of the TR0 files: DATALOC ADD RCI rci.ssec.wisc.edu LOGON GOPS 9999 IMGDISP RCI/NCDCR ID=DEN STA=DEN EU=WSR-BREF REFRESH='EG;MAP H;BAR' Beginning Image Data transfer, bytes= 1131724 IMGDISP: loaded frame 1 EG;MAP H;BAR IMGDISP: done Erased graphic frame(s) 1-1 EU: Restoring WSR-BREF.ET to frame(s)= 1 EU: Done MAP: Completed frame 1 Done Image Name ID Day Nominal Time Scan Time Band ---------------- --- ------- ------------ --------- ---- RCI/NCDCR DEN 20 May 14140 22:34:35 MISSING 1 File Nominal Image RAW BRIT ECHO VIP Lat/Lon Line/Element Line/Element DBZ 39:43:17 / 104:29:09 598/ 616 599/ 617 166 166 50.0 4 IMGDISP RCI/NCDCV ID=DEN STA=DEN EU=WSR-BVEL REFRESH='EG;MAP H;BAR' Beginning Image Data transfer, bytes= 1131724 IMGDISP: loaded frame 2 EG;MAP H;BAR IMGDISP: done Erased graphic frame(s) 2-2 MAP: Completed frame 2 EU: Restoring WSR-BVEL.ET to frame(s)= 2 EU: Done Done Image Name ID Day Nominal Time Scan Time Band ---------------- --- ------- ------------ --------- ---- RCI/NCDCV DEN 20 May 14140 22:34:35 MISSING 9 File Nominal Image RAW BRIT VEL Lat/Lon Line/Element Line/Element KT 39:49:59 / 104:34:06 515/ 569 516/ 570 122 122 -6 IMGPROBE: Done Looks like TC made the switch to use of SSEC v2015.1 and that things are now working in the same way as they are for me in Unidata McIDAS-X. NB: access to a TS0 file (RCI/NCDCS) shows an unexpected error: IMGDISP RCI/NCDCS ID=DEN STA=DEN EU=WSR-BREF REFRESH='EG;MAP H;BAR' IMGDISP: done IMGDISP failed, RC=2 As I noted in one of the emails I sent yesterday (Jim may have been the only recipient of that email), I was never given an example TS0 file to test. If Jim or you could put one or more out in anonymous FTP, I will grab it/them and test here. re: > Thanks again! No worries. Thanks for hanging in there! Cheers, Tom -- **************************************************************************** Unidata User Support UCAR Unidata Program (303) 497-8642 P.O. Box 3000 address@hidden Boulder, CO 80307 ---------------------------------------------------------------------------- Unidata HomePage http://www.unidata.ucar.edu **************************************************************************** Ticket Details =================== Ticket ID: CCM-472749 Department: Support McIDAS Priority: Normal Status: Closed