[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
20020607: GOES oversampling in element direction (cont.)
- Subject: 20020607: GOES oversampling in element direction (cont.)
- Date: Fri, 07 Jun 2002 09:23:34 -0600
>From: Darren Gallant <address@hidden>
>Organization: UCAR/JOSS
>Keywords: 200206051454.g55EsNJ12608 McIDAS GOES IMGDISP MAG
Darren,
>Thanks,
>
>Is sounder data displayed by individual bands or with certain bands
>combined?
You always display McIDAS images by individual band. You can create
products using multiple bands using IMGOPER. The output of IMGOPER
is an image containing a single "band", so it is displayable by
IMGDISP without having to specify the BAND= keyword.
>I assume the MAG keyword requires integer arguments.
Yes. The MAG= keyword results in a sampling of the original image if
the MAG= values are <=1. For blow-ups (MAG= values greater than 1), the
original pixels are replicated. The integral values of MAG=, therefore,
specify either the sampling interval or replication factor.
Tom
>From address@hidden Fri Jun 7 09:28:16 2002
>Subject: Re: 20020607: GOES oversampling in element direction (cont.)
Thanks,
Undata Support has been very helpful as usual.
Thanks again.
Darren
Darren R. Gallant UCAR/JOSS
Programmer/Technician Joint OfFice Of Science Support
303-497-2634 P.O. Box 3000
address@hidden Boulder,CO 80307-30000