This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Hi, On Mon, Sep 14, 2020 at 4:15 PM Tom Yoksas <address@hidden> wrote: > If the MD5 signatures differs > at all, the LDM will see them as being the same. > Tom meant to write If the MD5 signatures differs at all, the LDM will see them as *not* being the same Regards, Steve Emmerson Ticket Details =================== Ticket ID: BMK-187963 Department: Support LDM Priority: Normal Status: Closed =================== NOTE: All email exchanges with Unidata User Support are recorded in the Unidata inquiry tracking system and then made publicly available through the web. If you do not want to have your interactions made available in this way, you must let us know in each email you send to us.