[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[LDM #OXJ-933917]: LDM pqing setting xon/xoff
- Subject: [LDM #OXJ-933917]: LDM pqing setting xon/xoff
- Date: Thu, 24 Aug 2017 09:19:45 -0600
Hey Bill,
pqing(1) doesn't have the capability of disabling xon/off. I'll see about
adding it.
Can you rebuild the LDM if I send you a few replacement files?
What the heck are you guys ingesting, anyway? :-)
> Since upgrading our AWIPS which include the Os from RH6 to RH7 we have
> started to have dropped characters on the serial connection feeding a
> ldm system.
>
> Reducing the baud speed correct the character lost, but we then have
> products being dropped on the AWIPS side.
>
> This charadter lost we have traced to not having handshaking configured.
>
> Right now we ate trying to turn on xon/xoff. I know how to activate this
> on the AWIPS side.
>
> How is it can we do the same with pqing ?
>
> If xon/xoff does not correct the issue we are then gone to look at
> setting DSR.
>
> Here is the current line in ldmd.conf, right now -p none
>
> pqing -f IDS|DDPLUS -vl /usr/local/ldm/var/logs/wxwire-BCQ.log -b 115200 -p
> none /dev/ttyS0
Regards,
Steve Emmerson
Ticket Details
===================
Ticket ID: OXJ-933917
Department: Support LDM
Priority: Normal
Status: Closed
===================
NOTE: All email exchanges with Unidata User Support are recorded in the Unidata
inquiry tracking system and then made publicly available through the web. If
you do not want to have your interactions made available in this way, you must