This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Hi Charlie, re: > When products are transmitted, would ldm server complete the transmission if > we restart the server? If your LDM is shutdown before a product has finished transferring (for instance if the power went out, etc.), the product would be resent when the LDM is brought back up. If you shutdown your LDM using 'ldmadmin stop', then it will not stop until a transfer that is in progress finishes. In this case, the product will be in your LDM queue, but the 'pqact' instance that is setup to process the product might not run on the product before you shutdown your LDM. I hope the above was clear enough... Cheers, Tom -- **************************************************************************** Unidata User Support UCAR Unidata Program (303) 497-8642 P.O. Box 3000 address@hidden Boulder, CO 80307 ---------------------------------------------------------------------------- Unidata HomePage http://www.unidata.ucar.edu **************************************************************************** Ticket Details =================== Ticket ID: BET-183387 Department: Support LDM Priority: Normal Status: Closed