This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Gregg, > Attached are the files stored by LDM with the "WWUS.. ...." entry. > Hopefully they assist in diagnosing what is going on. This might be irrelevant or a red-herring, but the names of the files are inconsistent with the pqact(1) entries that you sent. The files are named "12030720.wwp8" and "12030819.wwp7". The pqact(1) entries are # WWP Product WMO ^WWUS40 KWNS ([0-3][0-9])([0-2][0-9]).*/pWWP FILE data/nwx/spc/wwp/(\1:yy)(\1:mm)\1\2.wwp # # TEST FOR TEST WATCH with OPCN and SPC WMO ^WWUS.. .... ([0-3][0-9])([0-2][0-9]) FILE data/nwx/spc/wwptest/(\1:yy)(\1:mm)\1\2 The file extensions ("wwp8" and "wwp7") are inconsistent with the pqact(1) entries. Those entries couldn't have created those files. Regards, Steve Emmerson Ticket Details =================== Ticket ID: OYP-784384 Department: Support LDM Priority: Normal Status: Closed