This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Gini, > Can you please advise on how to use a new feedtype, eg, NEXRD3, for > testing purposes? > > thanks > > Gini Galvin > Computer Specialist > NWS/TOC/TSB > > David S Alden wrote: > > Hi Gini, > > I am atempting to submit some Level III products to LDM on the > > development > > systems and I have immediately run into a problem. I've looked over the > > feedtypes already defined in the LDM and, of course, I don't want to use any > > that others are already using for other data. However, it would appear that > > a new feedtype "NEXRD3" would be appropriate for our purposes. What does > > Unidata say about an LDM feedtype enhancement for our purposes. What would > > it take to enhance the LDM-6.6.5 release to add "NEXRD3" for our testing > > purposes? Please advise. Thanks. The number of feedtypes is very limited, so use the EXP feedtype for experimenting. Be sure that the product-identifiers are easily distinguishable from anything else (they could, for example, start with "NEXRAD3" or some other easily-selected token). And don't allow the hosts that receive those data-products on the general IDD. Regards, Steve Emmerson Ticket Details =================== Ticket ID: OAO-873149 Department: Support LDM Priority: Normal Status: Closed