This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
John,
Your clock might be correct, but according to our LDM log file,
your LDM is still asking for data that's in the future:
Dec 21 08:24:34 uni7 adiabat.rwic.und.edu(feed)[31341] NOTE: Starting
Up(6.6.5/6): 20071221142433.210 TS_ENDT {{NEXRAD2, ".*"}},
SIG=594e9395cfbf4a3d842e2939be77ec3c, Primary
The above message was logged by an upstream LDM in response to
a connection from Adiabat. The connection occurred at
2007-12-21 08:24:34 UTC and a request was made for data beginning
at 2007-12-21 14:24:33.210 UTC. The fact that the request is
almost exactly 6 hours in the future and your timezone is -6
hours makes me suspect something funny with the timezone
information on your system. What's the output of the commands
"date -u" and "date"?
Regards,
Steve Emmerson