This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Gerry, > Sent this out and I'm trying to make sure I cover all the bases, so > here's our latest. > > The network engineers report that a fiber-optic jumper that hadn't been > touched or disturbed "for months" decided to start a slow degradation > process about 2 weeks ago, with acceleration a week ago and > near-catastrophic events over the weekend through today. The jumper has > been replaced. It is unclear to me whether another outage will be > required to perform another replacement and cleanup of the jumper at the > POP in Houston. > > ALSO: memtest86 was stopped at 52% with no errors. I'm gonna re-init > LDM and try it again. What's the worst that can happen? Complete annihilation of the spacetime continuum? :-) Good luck. Regards, Steve Emmerson Ticket Details =================== Ticket ID: IIX-893121 Department: Support LDM Priority: Normal Status: Closed