This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
>From: Celia Chen <address@hidden> >Organization: NCAR/RAP >Keywords: 200504111650.j3BGoJv2002156 IDD latenccy Hi Celia, >Thanks for the info. I did check the latency status of rasp on the realtime >statistics but didn't check the status of thelma. OK. The other thing you could do in a situation like this is use the LDM application 'notifyme' to see if your upstream feed host is getting the data you want and what sorts of latencies it is seeing. For instance: <as 'ldm' on rasp> notifyme -vxl- -f NEXRD2 -h thelma.ucar.edu >Could you setup thelma to feed the NEXTAD2 data to level at RAL in addition >to feeding rasp? You need to setup the request on 'level'. thelma.ucar.edu already has an allow line for this. >Thanks in advance. No worries. Cheers, Tom -- NOTE: All email exchanges with Unidata User Support are recorded in the Unidata inquiry tracking system and then made publicly available through the web. If you do not want to have your interactions made available in this way, you must let us know in each email you send to us.