This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Chris, >Date: Mon, 29 Dec 2003 11:49:41 -0600 >From: "Chris D Gilbert" <address@hidden> >Organization: NOAA/NWS/ROC >To: Steve Emmerson <address@hidden> >Subject: Re: 20031202: LDM Latency Question The above message contained the following: > Using the notifyme tool, I was able to confirm that the log messages > are grouped 30 seconds apart when I start my "pq_insert task" from > the /etc/rc2.d script. > > However, when I moved my "pq_insert task" into the ldmd.conf script > (using the exec command), I still get the same results. The notifyme > tool still shows the log messages 30 seconds apart. Do I need to do > anything else? That should have sufficed -- providing the "pq_insert task" program was coded to send SIGCONT signals to its process group. Was it? > Is anyone available to talk to over the phone this week? I'm here all week except Thursday from about 0830 to 1130 and from 1230 to 1700 MST. > We are using LDM 6.0.14 on both our client and server. That's good. > Thanks, > Chris Gilbert > LAB Phone (405) 366-6500 x2271 Regards, Steve Emmerson