This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Robert Leche wrote: > > Anne, > I have another question on on pqact.conf. I have added 4 entries to > Mistral.srcc.lsue.edu. The first entry causes data to be acquired but > the second though forth do not. I think I am beyond the tab space > problems in syntax. The LDM process is running with the other product > actively being produced. I see no errors in the logs. So are CDUS27, > CXUS4[2-6], and CDUS46 properly defined? > > > ######################################################### > # > # Climate Daily Summaries > DDS|PPS ^CSUS4[3-4]* .... ([0-3][0-9]) > FILE data/ddplus/climate/(\1:yy)(\1:mm)\1.asos > # > # > # Climate Daily Summaries > DDS|PPS ^CDUS27 .... ([0-3][0-9]) > FILE data/ddplus/climate/(\1:yy)(\1:mm)\1.asos > # > # > # Climate Daily Summaries > DDS|PPS ^CXUS4[2-6] .... ([0-3][0-9]) > FILE data/ddplus/climate/(\1:yy)(\1:mm)\1.asos > # > # Climate Daily Summaries > DDS|PPS ^CDUS46 .... ([0-3][0-9]) > FILE data/ddplus/climate/(\1:yy)(\1:mm)\1.asos > # > ######################################################## > # > > Bob > > > -- > > ---------------------------------------------------------------- > Robert Leche > System Administrator > Louisiana State University - Southern Regional Climate Center > 260 Howe-Russell Building > Baton Rouge, La. 70803 > address@hidden > 225 578 5023 > ---------------------------------------------------------------- > > Hi Bob, I don't see anything wrong with these entries. However, I can't tell if the fields are tab separated or not - the mailer often munges that stuff. You can always try running 'ldmadmin pqactcheck' and see if it reports any errors, although I suspect that if pqactcheck were to report an error pqact would not be running. And, keep in mind that some errors are possible that pqactcheck doesn't detect. The other reason for nothing being filed would be if you're not recieving those products. Try pqcat -v -l - -f "DDS|PPS" -p "^CDUS46 ... [0-3][0-9]" to see if any of those particular products are currently in your queue. And/or you can try notifyme -v -l - -f "DDS|PPS" -p "^CDUS46 ... [0-3][0-9]" to see those products as they arrive. Anne -- *************************************************** Anne Wilson UCAR Unidata Program address@hidden P.O. Box 3000 Boulder, CO 80307 ---------------------------------------------------- Unidata WWW server http://www.unidata.ucar.edu/ ****************************************************