[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

[IDV #LNF-527323]: error image vizualization

This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.


  • Subject: [IDV #LNF-527323]: error image vizualization
  • Date: Mon, 01 Feb 2021 10:13:01 -0700

> Full Name: dawid
> Email Address: address@hidden
> Organization: private
> Package Version: 5.6 build date:2019-05-23 20:13 UTC
> Operating System: Windows 8.1
> Hardware: Java: home: D:\Program Files\IDV_5.6\jre version: 1.8.0_51 
> j3d:1.6.0-pre12-daily-experimental daily
> Description of problem: Creating display: Image Display Over Topography
> topography units null must convertible with m or gpm
> topography units null must convertible with m or gpm
> 
> ******************
> Stack trace:

Hi Dawid,

The problem is that the topography field should have the unit as meter or 
convertible to meter.


Yuan