> Hello,
> 
> IDV seems to ignore the isosurface value selected in the Level tab. For
> example, when I select a geopotential height at isobaric surface to
> display at some initial value, say 700 hPa, IDV creates the surface and
> gives the value in gpm (say 8388.5 gpm). No matter what value is
> selected in the Level tab I get a gpm of 8388.5. If I later adjust the
> surface value using the slider it does alter the surface correctly.
> 
> Do you know what is causing this behavior? It seems the user-selected
> value in the Level tab is always ignored and a default is used.
> 
> Thanks.
> 
> --gary
> 
> 
Hi Gary,
     The isosurface is a 3D volume display, it will ignore the level. I am 
guessing that what you really wanted was a 3D surface display, not isosurface 
display.

Yuan