This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
> Hello,
>
> IDV seems to ignore the isosurface value selected in the Level tab. For
> example, when I select a geopotential height at isobaric surface to
> display at some initial value, say 700 hPa, IDV creates the surface and
> gives the value in gpm (say 8388.5 gpm). No matter what value is
> selected in the Level tab I get a gpm of 8388.5. If I later adjust the
> surface value using the slider it does alter the surface correctly.
>
> Do you know what is causing this behavior? It seems the user-selected
> value in the Level tab is always ignored and a default is used.
>
> Thanks.
>
> --gary
>
>
Hi Gary,
The isosurface is a 3D volume display, it will ignore the level. I am
guessing that what you really wanted was a 3D surface display, not isosurface
display.
Yuan