[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[IDV #MWG-305396]: Isosurface Value Ignored
- Subject: [IDV #MWG-305396]: Isosurface Value Ignored
- Date: Tue, 26 Jul 2011 11:11:15 -0600
> Hello,
>
> IDV seems to ignore the isosurface value selected in the Level tab. For
> example, when I select a geopotential height at isobaric surface to
> display at some initial value, say 700 hPa, IDV creates the surface and
> gives the value in gpm (say 8388.5 gpm). No matter what value is
> selected in the Level tab I get a gpm of 8388.5. If I later adjust the
> surface value using the slider it does alter the surface correctly.
>
> Do you know what is causing this behavior? It seems the user-selected
> value in the Level tab is always ignored and a default is used.
>
> Thanks.
>
> --gary
>
>
Hi Gary,
The isosurface is a 3D volume display, it will ignore the level. I am
guessing that what you really wanted was a 3D surface display, not isosurface
display.
Yuan
Ticket Details
===================
Ticket ID: MWG-305396
Department: Support IDV
Priority: Normal
Status: Closed