This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
> Yuan > > I guess I did not explain my issues adequately. Please see the comments > I've inserted below. Thanks. > > Bill > > On 2/3/2011 12:51 PM, Unidata IDV Support wrote: > >>>> Full Name: bill fingerhut > >>>> Email Address: address@hidden > >>>> Organization: lyndon state college retired > >>>> Package Version: 2.9u2 build date:2010-12-03 08:14 UTC > >>>> Operating System: Windows XP > >>>> Hardware: Java: home: C:\Program Files\IDV_2.9u2\jre version: 1.6.0_20 > >>>> j3d:1.5.2 fcs (build4) > >>>> Description of problem: > >>>> > >>>> I am currently looking at 2 height-time displays and a data probe/time > >>>> series. I believe everything is displayed according to the documentation; > >>>> however, I would like to suggest a couple of possible improvements. > >>>> > >>>> First, the 2 height-time displays share the same geographic point > >>>> (lat,lon). I don't see how to make the probe time series share this > >>>> location. Is it now possible ? > >> Hi Bill, > >> The sharing of the geo location of two probe point is possible in the IDV, > >> you need to turn the share in the display control panel. Edit> Sharing> > >> Sharing On. > > This was already done, and it does not work as we expect. The 2 height-time > displays share a point, but the probe time series does not. All 3 are > supposed > to be sharing the location point. Bill, It is my fault, I didn't read your report carefully. The time/height is a 3D probe and the time series is a 2D probe, to share the geo location of these two different spatial probe point may be complicated. I need more time to think about it. > > >>>> Second, the probe in the probe time series is easily customized via a > >>>> menu. I.e., the color and size can easily be changed. I don't see the > >>>> same capability with the height-time display. The color can be changed > >>>> by changing the selector color, but I don't see how to make the size of > >>>> the probe different. Can this be done ? > >> No, the size of the probe can not be changed. > > Bill, > > > > Sorry for this wrong information, the probe size can be changed. In the > > display control of the probe, Edit> Properties> Probe, you can change the > > size and shape, or you can do View> Probe>Size> Increase. > > I am aware of this. As I mentioned above, I see how to change the size > of the > probe in the probe time series display. I do not see how to change the size > of the probe in the height-time display. There is no probe tab in this > control > as there is in the other type of display control. > I think we can add this feature to increase the size of time/height probe. Yuan > > > > Yuan > >>>> Third, the time labels in the probe/time series are quite long - they > >>>> take > >>>> a lot of space, which reduces the number of time labels possible. The > >>>> time format looks like the default in user preferences? Could we use > >>>> the same time format used in the height-time display (day/hour)? I think > >>>> this would help the appearance quite a bit. > >>>> > >> This feature needs to be added, I will put it in the todo list. > >> > >> > >> Yuan > >>>> Just trying to help ! > >>> Hi Bill, > >>> Many Thanks for these improvement suggestions, I will check the source > >>> code after AMS to see how much work will involved to make these > >>> improvements. > >>> > >>> Yuan > >>>> > > > > Ticket Details > > =================== > > Ticket ID: BER-596188 > > Department: Support IDV > > Priority: Normal > > Status: Open > > > > > > > -- > The Fingerhuts > Saint Johnsbury, Vt, 05819 > > email: address@hidden > > Ticket Details =================== Ticket ID: BER-596188 Department: Support IDV Priority: Normal Status: Open