This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
> I created a Stuve display from a model run (Derived->Sounding Data > with true winds), then in the Control's panel, I did a > File->Save->Save Display as bundle. > > When I attempted to reload the bundle, a window popped up that said: > > "Please select data for: Stuve > Original field: Sounding Data (with true winds)" > > (Also got this when I used a Skew-T diagram....) > When you save a display as a bundle its really a display template - there is no data. When you load it interactively the user is prompted to select the data. > My goal is to create a bundle with this display and then use it in an > ISL script to create off-line movies of a time-series of Stuve (or > Skew-T). > > See the docs on the "display" tag. This supports specifying a display template bundle: http://www.unidata.ucar.edu/software/idv/docs/userguide/isl/DataAndDisplays.html#display -Jeff Ticket Details =================== Ticket ID: YBG-544676 Department: Support IDV Priority: Normal Status: Closed