This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.


  • Subject: [IDV #KDD-358203]: Range with exponent
  • Date: Wed, 21 Nov 2007 08:18:51 -0700

Hi Patrick-

> Full Name: Patrick Brockmann
> Email Address: address@hidden
> Organization: IPSL
> Package Version: 2.4b3 build date:2007-11-20 08:05 UTC
> Operating System: Linux
> Hardware: Java: home: /home/brock/IDV_2.4b3/jre version: 1.5.0_11 j3d:1.3.1
> Description of problem: When I load data with following range:
> Minimum value: 0
> Maximum value: 0.00046073
> Nothing appears.
> 
> Setting range with exponent 10 notation does nothing.
> Is there a way to map this field at this range ?

Use the Edit->Change Unit menu to include an exponent for the unit. 
For example, if your unit is seconds, change it to be 10E-6 sec.

BTW, it's easier for us if you submit a separate support request for
each topic.

Don Murray