This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Hi Rich- This is Don. > On 2/15/07, Unidata IDV Support <address@hidden> wrote: > > However, from the field selector there is a "Levels" > > tab in the data subset section (lower right). This allows you to select > > a single level (for plan views) as well as a level range (do > > a control-click or shift-click) for 3d displays. Basically, if you have 2 or > > more levels selected we take the min and max as the level range. > > Cool! I didn't see that -- you are right! I'm having a little > problem though. Selecting one level worked fine for a map view plot, > but then I tried selecting a vertical section display, but with only > the 1st 12 levels. IDV didn't complain, but showed me all 30 levels > anyway. Also when I exported the bundle, I get a funny grey slice on > my display, although the slice in the dashboard looks ok (except that > it's all 30 levels). > > Screengrab: > http://stellwagen.er.usgs.gov//models/adria/meteo/coamps3d_jan26_bug.gif > > Bundle: > http://stellwagen.er.usgs.gov//models/adria/meteo/coamps3d_jan26_bug.xidv > > Aren't you glad I'm active again? ; -) If it's a staggered grid and you ask for a derived parameter, we have to load in the entire grid. Otherwise, badness happens. ;-) Don Ticket Details =================== Ticket ID: QAE-416920 Department: Support IDV Priority: Normal Status: Open