This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Hi again Waldenio,
Quick update:
I was incorrect in something I said in my previous email: I _have_ been
ingesting the GOES-10 images from mopora. I was unable to access them
from home while writing my previous email because I evidently changed
where they were being stored, so my ADDE server configurations for the
data were incorrect. I found and fixed the problem right after sending
you my first reply.
I think that it would be useful for you to compare the imagery being
created by the CPTEC satellite division and that being made available
from our GOES-10 ingest machine. This can be done easily using an
ADDE-enabled application package like McIDAS-X, IDV, McIDAS-V. The details
of the servers are:
CPTEC imagery via ADDE server:
machine: yakov.unidata.ucar.edu
ADDE group: CPTEC
ADDE descriptors: GE-VIS, GE-WV, GE-IR
GOES-10 imagery via ADDE server:
machine: goessouth.unidata.ucar.edu
ADDE group: SOUTH
ADDE descriptor: SH
BAND 1 -> VIS
BAND 3 -> WV
BAND 4 -> IR
The things to remember when doing the comparisons are:
- the times assigned to the CPTEC images seem to be off by 15
minutes. For instance, the image marked as 15:00 seems to be
the 15:15 image
- the CPTEC images are blown-down to remove the GOES-10 oversampling
in the element (horizontal) direction; the images from the
goessouth.unidata.ucar.edu ADDE server are not blown down. This
will affect how the images need to be displayed so that a good
comparison can be made.
Two observations after comparing one image from each set:
- the CPTEC images seem to be shifted towards the west
- the brightness values in the CPTEC images seem to be greater than
the ones from our GOES-10 ingestor
I have included GIF files of today's 15:00 CPTEC and 15:15 Unidata-ingested
images to illustrate my observations above.
Cheers,
Tom
--
****************************************************************************
Unidata User Support UCAR Unidata Program
(303) 497-8642 P.O. Box 3000
address@hidden Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage http://www.unidata.ucar.edu
****************************************************************************
Ticket Details
===================
Ticket ID: LOR-884164
Department: Support IDD Brasil
Priority: Normal
Status: ClosedAttachment:
cptec_20081217_1500.gif
Description: GIF image
Attachment:
unidata_20081217_1515.gif
Description: GIF image