This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Hi Tomislav, HRS ^[YZ].B... KWBE ([0-3][0-9])([0-2][0-9][0-6][0-9]) FILE data/eta218/(\1:yyyy)(\1:mm)\1\2.grib Should file with naming convention: 200411101200.grib yyyymmddhhmm.grib Please let us know if you have issues with this...keep in mind, no spaces..only tabs, in pqact.conf I will be setting up your HRS (HDS) feed shortly. Cheers, Jeff --------------------------------------------------------------------- Jeff Weber address@hidden : Unidata Program Center PH:303-497-8676 : University Corp for Atmospheric Research 3300 Mitchell Ln : http://www.unidata.ucar.edu/staff/jweber Boulder,Co 80307-3000 : --------------------------------------------------------------------- On Mon, 8 Nov 2004, Tomislav Urban wrote: > Jeff - > > > > To follow up on this: > > > > When setting up the pqact.conf file for the nexrad feed we are using > something along these lines: > > > > NNEXRAD ...... .... (..)(..)(..) /p(N1P)(...) FILE -overwrite > -close /var/ldm/data/nexrad/n1p/(\1:yyyy)/(\1:mm)/(\1:dd)/\5/\4\5_\2\3 > > > > I guess we would need to know the feed name (equivalent of NNEXRAD) for > the eta model data and the products that are available within that feed > (i.e. the equivalent of n1p above). > > > > Thanks! > > > > - Tomislav > > > > -----Original Message----- > From: David Maidment [mailto:address@hidden] > Sent: Monday, November 08, 2004 12:22 PM > To: Jeff Weber > Cc: Tomislav Urban; Jon Goodall > Subject: Eta data streams > > > > Jeff: > > > > We are trying to ingest some products from the NCEP eta model from > > the Unidata data stream and we are not sure what data stream and what > > product we should be using. > > > > Tomislav Urban at TACC has installed LDM and is now successfully > > archiving > > some NIDS data. Thanks for your help with that. > > > > If you could guide us as to what data stream and product we should be > > using > > to get at eta, that would be great. > > > > David > > > > > > -----Original Message----- > > From: Tomislav Urban [mailto:address@hidden] > > Sent: Monday, November 08, 2004 12:14 PM > > To: David Maidment > > Subject: Followup > > > > > > David - > > > > I just wanted to make sure that you were still planning to send an > > introductory email to Anton Kruger and that you weren't waiting on me. > > > > Thanks! > > > > - Tomislav > >