Patrick,
The suominet parameters (shown in the suomi.pack file) are:
PRES pressure millibars
TMPC temperature celsius
PWVM Precipitable water vapor in millimeters
PWVE Precipitable water vapor format error millimeters
DELW wet delay millimeters
DELD Model Dry delay millimeters
DELT Total delay millimeters
DELF final delay
PIFC PI factor (conversion from wet delay to PWVM)
MFLG Met flag
For more information on the netCDF file, you can use "ncdump -h"
on the netcdf file.
I have set up NMAP2 with the the suominet data defined in the
prmlst.tbl for color coded plots.
Steve Chiswell
>From: "Patrick S. Market" <address@hidden>
>Organization: UCAR/Unidata
>Keywords: 200307021519.h62FJBLd021048
>Steve:
>
>Thanks for your help.
>
>
>Suomi is all working fine now, except that my display in GARP keeps
>coming up with a '0' for all PWAT values at all of the GPS stations.
>In the Garp-defaults file, I have specified
>
>suomi_parms: "PWAT*1000.0;TMPF;BLNK;SMSL;BLNK;DWPF;STID"
>
>I assumed that the PWAT values were shipped out in meters. Yet,
>both PWAT and PWAT*1000.0 both plot out a '0' in GARP.
>
>What do I need to do?
>
>Thanks again,
>Pat
>
>
>
>>
>>
>> Patrick,
>>
>> For dcsuomi, use only "-v" for verbose logging, not "-v 1"
>> as per the "dcsuomi -help" page.
>>
>>
>> Steve Chiswell
>>
>
>
>--
>========================================================================
>Dr. Patrick S. Market
>Dept. of Atmospheric Science
>University of Missouri-Columbia Phone: (573) 882 - 1496
>387 McReynolds Hall Fax: (573) 884 - 5133
>Columbia, MO 65211 USA E-mail: address@hidden
>========================================================================
>