[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
19990121: missing data...
- Subject: 19990121: missing data...
- Date: Thu, 21 Jan 1999 15:23:05 -0700
Maureen,
Our decoder output matches what you have shown below.
Basically there are 3 stations with missing temperatures
KOWB (every hour that they report) and KLOU and KEHR once each.
What you will find is that for these stations, you have received
their reports...and that TMPF isn't being stored for these reports.
If you use sfparm=tmpf;altm;text for example, you will see that there
are altimeter reports for Owensboro- even when no temp is stored.
On further examination of the KOWB report (note that they shut down between
5Z and 11Z) shows that they all have something in common in their temperature
report, eg:
KOWB 211945Z 17005KT 5SM BR SCT025 OVC040 18/ A2978=
^
|
TT/TdTd
OWB is reporting a temperature of 18C and not reporting a missing dewpoint.
The NWS code for decoding the METAR expects a missing dewpoint to
be included as MM, ie 18/MM, and therefore is not decoding the temparature
since it believes that this is an invalid format. I have fixed that
case in the decoder now.
In the case of KLOU, they actually did not report a temperature group
in their observation at that one hour, which is why the value is
stored as -9999.00.
I have posted 2 more updates in the gbuddy ftp area under
~gbuddy/nawips-5.4/patches/dcdmetar.c and dcdmtrmk.c
You can download these two routines and place in:
$GEMPAKHOME/src/bridge/metar
then update your copy of dchrly-
cd $GEMPAKHOME/src/bridge/metar
make clean
make
make clean
cd $GEMPAKHOME/src/programs/dc/dchrly
make clean
make all
make install
make clean
If you have more specific instances of reports that the decoder is not capable
of decoding, please let me know.
Steve Chiswell
>From: Maureen Ballard <address@hidden>
>Organization: UK Ag Weather Center
>Keywords: 199901211651.JAA14841
>Steve,
>
>Our main concern is with Kentucky since that is where we are so I am going to
>talking mainly about KY even though the problem most likely extends to other
>states. We are not presently keeping the raw data - it all goes through the dc
> hrly
>decoder to be stored and used in GEMPAK (since that is the only application we
> are
>presently using). Over the last 2 days, we are missing any where from 23 to 65
>observations from the 15 observing points in KY. Surprisingly enough, Henderso
> n
>(EHR) and Hopkinsville (HOP) have their entire data set. The other stations ar
> e
>missing as many as 10 observations in the 2 day period.
>
>Here is a list of the stations with temperature data for yesterday (1/20/99)
>through 16Z today (1/21/99):
>
> PARM = TMPF
>
>
> STN YYMMDD/HHMM TMPF
> SDF 990121/0000 55.90
> BWG 990121/0000 54.00
> EHR 990121/0000 48.20
> FFT 990121/0000 46.90
> FTK 990121/0000 53.60
> HOP 990121/0000 57.20
> JKL 990121/0000 55.90
> LOU 990121/0000 53.60
> LOZ 990121/0000 54.00
> OWB 990121/0000 -9999.00
> PAH 990121/0000 55.00
> SME 990121/0000 55.40
> BWG 990121/0100 51.10
> EHR 990121/0100 44.60
> FFT 990121/0100 46.00
> FTK 990121/0100 48.20
> HOP 990121/0100 57.20
> LOU 990121/0100 50.00
> LOZ 990121/0100 51.10
> OWB 990121/0100 -9999.00
> SME 990121/0100 51.80
> BWG 990121/0200 55.90
> EHR 990121/0200 42.80
> FFT 990121/0200 45.00
> FTK 990121/0200 50.00
> HOP 990121/0200 55.40
> LOU 990121/0200 48.20
> LOZ 990121/0200 50.00
> OWB 990121/0200 -9999.00
> SME 990121/0200 50.00
> BWG 990121/0300 52.00
> EHR 990121/0300 44.60
> FTK 990121/0300 50.00
> HOP 990121/0300 53.60
> LOU 990121/0300 48.20
> OWB 990121/0300 -9999.00
> SME 990121/0300 48.20
> LEX 990121/0400 48.90
> SDF 990121/0400 50.00
> BWG 990121/0400 51.10
> CVG 990121/0400 46.90
> EHR 990121/0400 46.40
> FTK 990121/0400 50.00
> HOP 990121/0400 53.60
> JKL 990121/0400 53.10
> LOU 990121/0400 51.80
> LOZ 990121/0400 48.00
> OWB 990121/0400 -9999.00
> PAH 990121/0400 51.10
> SME 990121/0400 46.40
> SDF 990121/0500 48.90
> CVG 990121/0500 46.00
> EHR 990121/0500 48.20
> FTK 990121/0500 48.20
> HOP 990121/0500 55.40
> JKL 990121/0500 53.10
> LOU 990121/0500 46.40
> OWB 990121/0500 -9999.00
> PAH 990121/0500 54.00
> LEX 990121/0600 48.00
> SDF 990121/0600 48.00
> CVG 990121/0600 46.00
> EHR 990121/0600 46.40
> FTK 990121/0600 48.20
> HOP 990121/0600 57.20
> JKL 990121/0600 52.00
> LOU 990121/0600 50.00
> PAH 990121/0600 57.00
> SME 990121/0600 51.80
> LEX 990121/0700 48.90
> SDF 990121/0700 48.90
> BWG 990121/0700 48.90
> CVG 990121/0700 46.00
> EHR 990121/0700 51.80
> FTK 990121/0700 50.00
> HOP 990121/0700 57.20
> JKL 990121/0700 51.10
> LOU 990121/0700 50.00
> PAH 990121/0700 55.90
> SME 990121/0700 53.60
> BWG 990121/0800 55.90
> EHR 990121/0800 51.80
> FFT 990121/0800 48.90
> FTK 990121/0800 51.80
> HOP 990121/0800 57.20
> LOU 990121/0800 48.20
> LOZ 990121/0800 51.10
> SME 990121/0800 55.40
> SDF 990121/0900 50.00
> BWG 990121/0900 59.00
> CVG 990121/0900 46.00
> EHR 990121/0900 51.80
> FFT 990121/0900 50.00
> FTK 990121/0900 51.80
> HOP 990121/0900 57.20
> JKL 990121/0900 51.10
> LOU 990121/0900 50.00
> LOZ 990121/0900 54.00
> PAH 990121/0900 59.00
> SME 990121/0900 55.40
> LEX 990121/1000 52.00
> SDF 990121/1000 51.10
> CVG 990121/1000 46.00
> EHR 990121/1000 53.60
> FFT 990121/1000 50.00
> FTK 990121/1000 53.60
> HOP 990121/1000 59.00
> JKL 990121/1000 53.10
> LOU 990121/1000 51.80
> LOZ 990121/1000 55.00
> PAH 990121/1000 60.10
> SME 990121/1000 57.20
> BWG 990121/1100 59.00
> EHR 990121/1100 53.60
> FFT 990121/1100 52.00
> FTK 990121/1100 53.60
> HOP 990121/1100 60.80
> LOU 990121/1100 -9999.00
> LOZ 990121/1100 54.00
> SME 990121/1100 57.20
> LEX 990121/1200 54.00
> SDF 990121/1200 48.90
> BWG 990121/1200 59.00
> CVG 990121/1200 46.00
> EHR 990121/1200 53.60
> FFT 990121/1200 51.10
> FTK 990121/1200 55.40
> HOP 990121/1200 59.00
> JKL 990121/1200 55.00
> LOU 990121/1200 50.00
> LOZ 990121/1200 55.90
> OWB 990121/1200 -9999.00
> PAH 990121/1200 59.00
> SME 990121/1200 57.20
> LEX 990121/1300 55.00
> SDF 990121/1300 50.00
> BWG 990121/1300 60.10
> CVG 990121/1300 46.00
> EHR 990121/1300 53.60
> FFT 990121/1300 51.10
> FTK 990121/1300 57.20
> HOP 990121/1300 62.60
> JKL 990121/1300 53.10
> LOU 990121/1300 51.80
> LOZ 990121/1300 57.90
> OWB 990121/1300 -9999.00
> PAH 990121/1300 59.00
> LEX 990121/1400 55.90
> SDF 990121/1400 50.00
> BWG 990121/1400 61.00
> CVG 990121/1400 46.90
> EHR 990121/1400 51.80
> FFT 990121/1400 52.00
> FTK 990121/1400 59.00
> HOP 990121/1400 64.40
> JKL 990121/1400 55.00
> LOU 990121/1400 51.80
> LOZ 990121/1400 57.90
> OWB 990121/1400 -9999.00
> PAH 990121/1400 60.10
> SME 990121/1400 60.80
> LEX 990121/1500 57.90
> SDF 990121/1500 52.00
> BWG 990121/1500 61.00
> CVG 990121/1500 46.90
> EHR 990121/1500 53.60
> FFT 990121/1500 53.10
> FTK 990121/1500 59.00
> HOP 990121/1500 64.40
> JKL 990121/1500 55.90
> LOU 990121/1500 51.80
> LOZ 990121/1500 59.00
> OWB 990121/1500 -9999.00
> PAH 990121/1500 61.00
> SME 990121/1500 62.60
> SDF 990121/1600 54.00
> BWG 990121/1600 63.00
> CVG 990121/1600 48.00
> FFT 990121/1600 57.90
> FTK 990121/1600 60.80
> HOP 990121/1600 66.20
> JKL 990121/1600 60.10
> LOU 990121/1600 55.40
> LOZ 990121/1600 60.10
> OWB 990121/1600 -9999.00
> PAH 990121/1600 63.00
> SME 990121/1600 64.40
>
> LEX 990120/0000 46.90
> SDF 990120/0000 48.00
> BWG 990120/0000 46.90
> CVG 990120/0000 46.00
> EHR 990120/0000 -9999.00
> FFT 990120/0000 46.90
> FTK 990120/0000 50.00
> HOP 990120/0000 55.40
> JKL 990120/0000 50.00
> LOU 990120/0000 48.20
> LOZ 990120/0000 48.90
> OWB 990120/0000 -9999.00
> PAH 990120/0000 54.00
> SME 990120/0000 50.00
> LEX 990120/0100 45.00
> SDF 990120/0100 48.00
> BWG 990120/0100 46.00
> CVG 990120/0100 46.00
> EHR 990120/0100 51.80
> FFT 990120/0100 45.00
> FTK 990120/0100 50.00
> HOP 990120/0100 55.40
> JKL 990120/0100 48.90
> LOU 990120/0100 48.20
> LOZ 990120/0100 48.00
> OWB 990120/0100 -9999.00
> PAH 990120/0100 55.00
> SME 990120/0100 48.20
> LEX 990120/0200 45.00
> SDF 990120/0200 48.00
> BWG 990120/0200 48.90
> CVG 990120/0200 44.10
> EHR 990120/0200 48.20
> FFT 990120/0200 45.00
> FTK 990120/0200 50.00
> HOP 990120/0200 55.40
> JKL 990120/0200 48.00
> LOU 990120/0200 50.00
> LOZ 990120/0200 46.90
> OWB 990120/0200 -9999.00
> PAH 990120/0200 53.10
> SME 990120/0200 46.40
> LEX 990120/0300 43.00
> SDF 990120/0300 46.90
> BWG 990120/0300 50.00
> CVG 990120/0300 44.10
> EHR 990120/0300 44.60
> FFT 990120/0300 45.00
> FTK 990120/0300 50.00
> HOP 990120/0300 55.40
> JKL 990120/0300 46.90
> LOU 990120/0300 50.00
> LOZ 990120/0300 45.00
> OWB 990120/0300 -9999.00
> PAH 990120/0300 52.00
> SME 990120/0300 46.40
> LEX 990120/0400 45.00
> SDF 990120/0400 46.90
> BWG 990120/0400 45.00
> CVG 990120/0400 43.00
> EHR 990120/0400 44.60
> FFT 990120/0400 46.00
> FTK 990120/0400 50.00
> HOP 990120/0400 53.60
> JKL 990120/0400 46.90
> LOU 990120/0400 48.20
> LOZ 990120/0400 41.00
> OWB 990120/0400 -9999.00
> PAH 990120/0400 53.10
> SME 990120/0400 46.40
> LEX 990120/0500 46.00
> SDF 990120/0500 46.90
> BWG 990120/0500 46.00
> CVG 990120/0500 41.00
> EHR 990120/0500 42.80
> FFT 990120/0500 43.00
> FTK 990120/0500 46.40
> HOP 990120/0500 53.60
> JKL 990120/0500 48.00
> LOU 990120/0500 46.40
> LOZ 990120/0500 42.10
> PAH 990120/0500 52.00
> SME 990120/0500 46.40
> LEX 990120/0600 45.00
> SDF 990120/0600 46.00
> BWG 990120/0600 46.90
> CVG 990120/0600 41.00
> EHR 990120/0600 44.60
> FFT 990120/0600 45.00
> FTK 990120/0600 44.60
> HOP 990120/0600 53.60
> JKL 990120/0600 48.00
> LOU 990120/0600 46.40
> LOZ 990120/0600 45.00
> PAH 990120/0600 51.10
> SME 990120/0600 48.20
> LEX 990120/0700 46.00
> SDF 990120/0700 44.10
> BWG 990120/0700 46.00
> CVG 990120/0700 39.00
> EHR 990120/0700 46.40
> FFT 990120/0700 44.10
> FTK 990120/0700 42.80
> HOP 990120/0700 53.60
> JKL 990120/0700 48.00
> LOU 990120/0700 46.40
> LOZ 990120/0700 44.10
> PAH 990120/0700 42.10
> SME 990120/0700 48.20
> LEX 990120/0800 43.00
> SDF 990120/0800 43.00
> BWG 990120/0800 46.90
> CVG 990120/0800 39.90
> EHR 990120/0800 41.00
> FFT 990120/0800 43.00
> FTK 990120/0800 41.00
> HOP 990120/0800 48.20
> JKL 990120/0800 48.00
> LOU 990120/0800 42.80
> LOZ 990120/0800 43.00
> PAH 990120/0800 43.00
> SME 990120/0800 48.20
> LEX 990120/0900 43.00
> SDF 990120/0900 43.00
> BWG 990120/0900 45.00
> CVG 990120/0900 39.00
> EHR 990120/0900 39.20
> FFT 990120/0900 39.90
> FTK 990120/0900 42.80
> HOP 990120/0900 41.00
> JKL 990120/0900 44.10
> LOU 990120/0900 44.60
> LOZ 990120/0900 41.00
> PAH 990120/0900 39.00
> SME 990120/0900 44.60
> LEX 990120/1000 42.10
> SDF 990120/1000 42.10
> BWG 990120/1000 41.00
> CVG 990120/1000 39.00
> EHR 990120/1000 37.40
> FFT 990120/1000 41.00
> FTK 990120/1000 42.80
> HOP 990120/1000 42.80
> JKL 990120/1000 39.90
> LOU 990120/1000 42.80
> LOZ 990120/1000 41.00
> PAH 990120/1000 37.00
> SME 990120/1000 44.60
> LEX 990120/1100 42.10
> SDF 990120/1100 41.00
> BWG 990120/1100 42.10
> CVG 990120/1100 39.90
> EHR 990120/1100 33.80
> FFT 990120/1100 41.00
> FTK 990120/1100 39.20
> HOP 990120/1100 41.00
> JKL 990120/1100 39.00
> LOU 990120/1100 44.60
> LOZ 990120/1100 41.00
> PAH 990120/1100 37.00
> SME 990120/1100 44.60
> LEX 990120/1200 39.90
> SDF 990120/1200 39.90
> BWG 990120/1200 37.90
> CVG 990120/1200 37.90
> EHR 990120/1200 33.80
> FFT 990120/1200 37.90
> FTK 990120/1200 37.40
> HOP 990120/1200 39.20
> JKL 990120/1200 39.00
> LOU 990120/1200 42.80
> LOZ 990120/1200 43.00
> OWB 990120/1200 -9999.00
> PAH 990120/1200 35.10
> SME 990120/1200 44.60
> LEX 990120/1300 39.90
> SDF 990120/1300 41.00
> CVG 990120/1300 37.90
> EHR 990120/1300 33.80
> FFT 990120/1300 39.90
> FTK 990120/1300 39.20
> HOP 990120/1300 39.20
> JKL 990120/1300 39.00
> LOU 990120/1300 41.00
> LOZ 990120/1300 41.00
> OWB 990120/1300 -9999.00
> PAH 990120/1300 33.10
> SME 990120/1300 42.80
> LEX 990120/1400 41.00
> SDF 990120/1400 41.00
> BWG 990120/1400 39.00
> CVG 990120/1400 39.00
> EHR 990120/1400 37.40
> FFT 990120/1400 39.90
> FTK 990120/1400 42.80
> HOP 990120/1400 39.20
> JKL 990120/1400 39.90
> LOU 990120/1400 48.20
> LOZ 990120/1400 42.10
> OWB 990120/1400 -9999.00
> PAH 990120/1400 34.00
> LEX 990120/1500 46.00
> SDF 990120/1500 45.00
> BWG 990120/1500 46.90
> CVG 990120/1500 45.00
> EHR 990120/1500 44.60
> FFT 990120/1500 45.00
> FTK 990120/1500 46.40
> HOP 990120/1500 50.00
> JKL 990120/1500 44.10
> LOU 990120/1500 46.40
> LOZ 990120/1500 46.90
> OWB 990120/1500 -9999.00
> PAH 990120/1500 43.00
> SME 990120/1500 53.60
> LEX 990120/1600 50.00
> SDF 990120/1600 48.90
> BWG 990120/1600 55.00
> CVG 990120/1600 48.90
> EHR 990120/1600 48.20
> FFT 990120/1600 50.00
> FTK 990120/1600 51.80
> HOP 990120/1600 57.20
> JKL 990120/1600 46.90
> LOU 990120/1600 51.80
> LOZ 990120/1600 52.00
> OWB 990120/1600 -9999.00
> PAH 990120/1600 52.00
> SME 990120/1600 57.20
> LEX 990120/1700 54.00
> SDF 990120/1700 54.00
> BWG 990120/1700 59.00
> CVG 990120/1700 52.00
> EHR 990120/1700 53.60
> FFT 990120/1700 53.10
> FTK 990120/1700 55.40
> HOP 990120/1700 60.80
> JKL 990120/1700 51.10
> LOU 990120/1700 55.40
> LOZ 990120/1700 57.00
> PAH 990120/1700 55.90
> SME 990120/1700 60.80
> LEX 990120/1800 55.90
> SDF 990120/1800 57.00
> BWG 990120/1800 61.00
> CVG 990120/1800 54.00
> EHR 990120/1800 55.40
> FFT 990120/1800 55.90
> FTK 990120/1800 57.20
> HOP 990120/1800 60.80
> JKL 990120/1800 55.00
> LOU 990120/1800 57.20
> LOZ 990120/1800 57.90
> OWB 990120/1800 -9999.00
> PAH 990120/1800 59.00
> SME 990120/1800 62.60
> LEX 990120/1900 57.00
> SDF 990120/1900 57.90
> BWG 990120/1900 63.00
> CVG 990120/1900 55.00
> EHR 990120/1900 57.20
> FFT 990120/1900 57.00
> FTK 990120/1900 62.60
> HOP 990120/1900 66.20
> JKL 990120/1900 57.90
> LOU 990120/1900 59.00
> LOZ 990120/1900 61.00
> OWB 990120/1900 -9999.00
> PAH 990120/1900 62.10
> SME 990120/1900 66.20
> BWG 990120/2000 64.90
> EHR 990120/2000 59.00
> FFT 990120/2000 59.00
> FTK 990120/2000 62.60
> HOP 990120/2000 68.00
> LOU 990120/2000 60.80
> LOZ 990120/2000 62.10
> OWB 990120/2000 -9999.00
> SME 990120/2000 69.80
> EHR 990120/2100 60.80
> FTK 990120/2100 62.60
> HOP 990120/2100 68.00
> LEX 990120/2200 57.00
> SDF 990120/2200 60.10
> EHR 990120/2200 55.40
> FTK 990120/2200 60.80
> HOP 990120/2200 68.00
> JKL 990120/2200 59.00
> OWB 990120/2200 -9999.00
> PAH 990120/2200 62.10
> SME 990120/2200 64.40
> LEX 990120/2300 55.00
> SDF 990120/2300 59.00
> BWG 990120/2300 61.00
> EHR 990120/2300 53.60
> FFT 990120/2300 52.00
> FTK 990120/2300 55.40
> HOP 990120/2300 60.80
> JKL 990120/2300 57.00
> LOU 990120/2300 57.20
> LOZ 990120/2300 59.00
> PAH 990120/2300 57.90
> SME 990120/2300 59.00
>
>
>I know it is pretty lengthy. Our biggest concerns are with LEX, SDF, PAH and J
> KL
>as they are our big cities. Any ideas as to why this is happening? What LDM en
> try
>would I put into our pqact.conf to keep the raw format and how would I look at
> it?
>That would at least eliminate dchrly as a culprit, correct?
>
>Thanks for any help - any more questions, let me know.
>
>Maureen
>
>Unidata Support wrote:
>
>> >From: Maureen Ballard <address@hidden>
>> >Organization: UK Ag Weather Center
>> >Keywords: 199901211420.HAA20651
>>
>> >Once again we are finding that we occasionally miss data. Yesterday
>> >(1/20/99) the last time stamp we got for the surface data in GEMPAK was
>> >19:47 local time (Eastern). Granted the new file should begin at 7
>> >Eastern (0Z), but it seems that the last time we had problems receiving
>> >data the same thing happened.
>>
>> Actually, reports from 2345Z through 0044Z are stored as 00Z observations
>> (thus you should see the next day file storing 00Z data before 00Z)
>> since most surface observations are taken before the top of the hour.
>> >
>> >Bottom line is that we are not receiving the all the data each hour.
>> >Last time I wrote Don said that they were missing some data on the
>> >McIdas stuff but not all of the same stuff I was missing thus it may be
>> >a problem with dchourly. Any ideas?
>>
>> I need some more information on what you think you are missing
>> since I have no idea what exactly you are pointing to.
>>
>> If you are storing both the raw observations, as well as decoding
>> the data with dchrly, and you are seeing the raw observations
>> not stored in the decoded file, then we need to see why that is happening.
>>
>> Any raw files, as well as your decoded file would help, as well
>> as specific stations you can point to.
>>
>> >
>> >If you want a copy of any files from here, just let me know - didn't
>> >want to send lots of stuff you didn't need.
>> >
>> >Thanks
>> >
>> >Maureen
>> >
>>
>> Steve Chiswell
>> Unidata User Support
>> ****************************************************************************
>> Unidata User Support UCAR Unidata Program
>> (303)497-8644 P.O. Box 3000
>> address@hidden Boulder, CO 80307
>> ----------------------------------------------------------------------------
>> Unidata WWW Service http://www.unidata.ucar.edu/
>> ****************************************************************************
>
>
>