This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
>From: Robert Mullenax <address@hidden> >Organization: . >Keywords: 199901191439.HAA10295 >I have looked through all info I can find on GARP, and cannot find >the answer to this. Is it possible to change the levels that are >available on the upper-air selection? I would like to have the option >of looking at 30, 20 and 10mb, instead of going from 50mb to top. >I know this is a breeze with the command line, but I would like to >be able to do it with GARP. > >Thanks, >Robert Mullenax > Robert, The Widget defaults are defined in the $GARPHOME/config/Garp_defaults file. In this file you will find a line: upalevels : Surface,1000,925,850,700,500,400,300,250,200,150,100,70,50,Top All you need to do is edit the level list and restart Garp. Steve Chiswell Unidata User Suport