This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
John, The NAM/ETA grid #212 was and has been in the data stream as shown through: http://motherlode.ucar.edu/cgi-bin/ldm/conduit_reception.csh However, as you ran the notifyme command below on May 02 01:15:20 and for the "-o 10000" which extends back to 20060501222840.830 There was no NAM data in the queue at that time. In fact, the 18Z run for May 01 was complete by 20:54:57, so you would not see that in your notifyme command. The 00Z run for May 02 began posting at "01:47:35". Again, outside of your request range. Since the RUC is hourly, you managed to pick a period where the data was available and in the queue. The product queue for idd.unidata.ucar.edu holds between 8000 and 10000 seconds of data. Delving into the LDM logs here, I see that you have 2 request patterns to idd.unidata.ucar.edu for CONDUIT data, eg: us20km.*F000 and (awip3d|sgrib20|bgrib20).*F001 That second line which requets NAM 212 grids (awip3d) won't match anything, since there are no F001 NAM 212 grids in CONDUIT. Your ldmd.conf file must have been modified recently if you had previously had a working request line for NAM 212. Steve Chiswell Unidata User Support > Institution: Museum of Science, Boston MA > Package Version: N/A > Operating System: N/A > Hardware Information: N/A > Inquiry: It appears that within the last day or so we have lost all ETA data > on CONDUIT from idd.unidata.ucar.edu. In particular we use grid #212 (grid > name awip3d). RUC2 seems fine. > > $ notifyme -h idd.unidata.ucar.edu -l - -v -f CONDUIT -p awip3d -o 10000 > May 02 01:15:20 notifyme[11101] NOTE: Starting Up: idd.unidata.ucar.edu: > 20060501222840.830 TS_ENDT {{CONDUIT, "awip3d"}} > May 02 01:15:20 notifyme[11101] NOTE: LDM-5 desired product-class: > 20060501222840.830 TS_ENDT {{CONDUIT, "awip3d"}} > May 02 01:15:21 notifyme[11101] NOTE: NOTIFYME(idd.unidata.ucar.edu): OK > <... waited 10 minutes - no output ...> > > $ notifyme -h idd.unidata.ucar.edu -l - -v -f CONDUIT -p E > TA -o 10000 > May 02 01:16:06 notifyme[11198] NOTE: Starting Up: idd.unidata.ucar.edu: > 20060501222926.234 TS_ENDT {{CONDUIT, "ETA"}} > May 02 01:16:06 notifyme[11198] NOTE: LDM-5 desired product-class: > 20060501222926.234 TS_ENDT {{CONDUIT, "ETA"}} > May 02 01:16:06 notifyme[11198] NOTE: NOTIFYME(idd.unidata.ucar.edu): OK > <... no output ...> > > RUC works fine... > $ notifyme -h idd.unidata.ucar.edu -l - -v -f CONDUIT -p RUC -o 10000 > May 02 01:16:53 notifyme[11221] NOTE: Starting Up: idd.unidata.ucar.edu: > 20060501223013.237 TS_ENDT {{CONDUIT, "RUC"}} > May 02 01:16:53 notifyme[11221] NOTE: LDM-5 desired product-class: > 20060501223013.237 TS_ENDT {{CONDUIT, "RUC"}} > May 02 01:16:53 notifyme[11221] NOTE: NOTIFYME(idd.unidata.ucar.edu): OK > May 02 01:16:54 notifyme[11221] INFO: 76284 20060501223540.307 CONDUIT 000 > > /afs/.nwstg.nws.noaa.gov/ftp/SL.us008001/ST.opnl/MT.ruc_CY.22/RD.20060501/PT.grid_DF.gr1/fh.anal_tl.press_gr.sgrib20 > !grib/ncep/RUC2/#252/200605012200/F000/MSLMA/MSL! 000000 > May 02 01:16:54 notifyme[11221] INFO: 76284 20060501223542.407 CONDUIT 005 > > /afs/.nwstg.nws.noaa.gov/ftp/SL.us008001/ST.opnl/MT.ruc_CY.22/RD.20060501/PT.grid_DF.gr1/fh.anal_tl.press_gr.sgrib20 > !grib/ncep/RUC2/#252/200605012200/F000/DEPR/2_m_above_gnd! 000005 > > > > Ticket Details =================== Ticket ID: DKG-189047 Department: Support IDD Priority: Normal Status: Closed