[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[AWIPS #TSM-138530]: AWIPS GFS LAMP Ceiling and Visibility Question
- Subject: [AWIPS #TSM-138530]: AWIPS GFS LAMP Ceiling and Visibility Question
- Date: Tue, 29 Nov 2022 10:49:03 -0600
> AWIPS/UCAR,
>
> I was looking at the GFS LAMP2p5 model output data for both ceiling and
> visibility. There should be at least 25 hours of data in the inventory but
> only 2 hours of data will actually plot a 19Z and 20Z image.
>
> Using the GFS LAMP Convective and Lightning data there are 25 hours of data
> available to the user. Am I missing something?
Hello,
Looking into this, it looks like there weren't any specific purge rules for GFS
LAMP data, so it was using the default of 2 versions which was why you were
only seeing 2 hours worth of data. I've added a new purge rule specific for GFS
LAMP to keep 25 versions (hours). Within the next 24 hours you should be seeing
more data.
Thanks,
Tiffany Meyer
AWIPS Lead Software Engineer
UCAR-Unidata