This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
> Hi Michael - > > Adam Clark over NSSL sent me a link to view their data from their WRF version. > ftp://ftp.nssl.noaa.gov/users/kain/ > > The data is in grib (not grib2) format. > > I attempted to drop the file in the edex manual data ingest folder and the > log shows it ingested and processed the file, but I don't see anything new in > my data browser. > > Would I need to add the model into the system, or would it merely > ingest/process and provide the model number, center number and id in the data > browser? The file saved to /data_store/manual/ after process, but I don't see > an hdf5 file. Hi Justin, In order to add a new grid you have to add a navigation file and a reference to the grid, it's all covered in the document Adding a New Grid to EDEX: https://docs.google.com/document/d/1l-bYkog_tmBQTj_x887q6QNFFtudaGfWIPIc7Q1b9wc/edit?usp=sharing Once you have the new definition file in /awips2/edex/data/utility/edex_static/site/OAX/grib/grids/ and the reference in /awips2/edex/data/utility/edex_static/site/OAX/grib/models/, you will have to copy+edit existing menu XML files in the localization perspective (or you can directly edit the base localization files on EDEX but that risks deleting your changes when a "yum groupupdate" is issued. Ticket Details =================== Ticket ID: GHJ-801255 Department: Support AWIPS Priority: Normal Status: Open