[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
[McIDAS #DXH-400982]: AREA max number limitation
- Subject: [McIDAS #DXH-400982]: AREA max number limitation
- Date: Tue, 13 Dec 2011 12:53:30 -0700
Hi Mary Ellen,
re:
> So, if the temperature values for the G15 data are off then it's a no
> brainer that we'll need a software upgrade regardless of the IMGREMAP issue.
Correct.
re:
> Is this a result of the calibration coefficient being incorrect in the
> version we're running?
Yes, the calibration coefficients included in Unidata McIDAS-X v2009 previous
to the one I am putting together now were estimates/preliminary values provided
to SSEC. The coefficients have been updated to match the operational GOES-15.
re:
> Note, there are no permission issues in the directories as we have tested
> this on several different machines and users etc.
Here's the thing: IMGREMAP copies over the satellite imagery from the server
into a local copy. IMGDISP also copies over the satellite imagery from
the same server, so I am not sure why one would work and the other fail.
Cheers,
Tom
--
****************************************************************************
Unidata User Support UCAR Unidata Program
(303) 497-8642 P.O. Box 3000
address@hidden Boulder, CO 80307
----------------------------------------------------------------------------
Unidata HomePage http://www.unidata.ucar.edu
****************************************************************************
Ticket Details
===================
Ticket ID: DXH-400982
Department: Support McIDAS
Priority: Normal
Status: Closed