This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
>From: =?ISO-8859-1?Q?Christian_Pag=E9?= <address@hidden> >Organization: UQAM >Keywords: 200410041955.i94JtvUE015904 McIDAS SFCMG TYPE=ALL Hi Christian, >I don't know if anybody stumbled about this particular problem. When >using SFCMG with TYPE=ALL, the latest obs is not taken into account >for line graphs in the meteogram, e.g. T, Td and P. Is it your observation that the latest hourly hob _is_ included, but the latest specials are not? The reason I ask is that I just plotted a meteorogram for KDEN specifying the TYPE=ALL keyword and do see the most currently hourly obs. >It is fine when >omitting TYPE=ALL. However, I am still running McIDAS v2003, so if it >was fixed in later version, please disregards. I will upgrade soon >anyway. Can you let us know when you see a good example of the failure so that this can be investigated better? Thanks! >Many thanks, Cheers, Tom -- +-----------------------------------------------------------------------------+ * Tom Yoksas UCAR Unidata Program * * (303) 497-8642 (last resort) P.O. Box 3000 * * address@hidden Boulder, CO 80307 * * Unidata WWW Service http://www.unidata.ucar.edu/* +-----------------------------------------------------------------------------+