Hi, i am enclosing 2 area files which represent the results of Tony Schreiners Co2 Absorption technique. They are a cloud top pressure file for both Goes 12 and Goes 10 for roughly the same hour. We would like to combine the information of the two area files onto one common grid over CONUS (presumably using IMGREMAP PRO=RECT) at full resolution, then extract the data out of area format (using axform) and finally reading that output and placing it into another database. We would then repeat process for all other times we have collected. I am having trouble with the first step. Can you provide help here? From address@hidden Wed Oct 29 06:55:22 2003 Followup to the original email. if you do an IMGPROBE on the initial AREA files there are values for PROD BM , CTP BM and CLDT KGED....i believe BM stands for millibars and KGED stands for Degrees K. At any rate it is the CTP value i am interested in not the brightness temperature. thanks, thanks, Randy Alliss
Attachment:
AREA1000
Description: Binary data
Attachment:
AREA1001
Description: Binary data