This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
>From: "Paul L. Sirvatka" <address@hidden> >Organization: College of DuPage >Keywords: 200109281354.f8SDsC118602 McIDAS-X 7.80 MAP SFCCON Paul, >OK...It is a schema problem in the 6 min data. I think we had this >before...and I forgot the fix. It does work with other servers. > >Any help? Here is what I would try: o copy the version of SCHEMA that comes with the version of McIDAS you are using (~mcidas/data/SCHEMA) to the directory where the 6-minute profiler MD files get written o delete the current day's 6-minute profiler MD file As new data comes in, check to see if the schema in the newly created 6-minute profiler file is what it should be: WPR6. Tom