This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
>From: Erick Lorenz <address@hidden> >Organization: UC Davis >Keywords: 200010092026.e99KQR407535 McIDAS-X MCGUI ROUTE Erick, >On at least one of my classroom workstations, when I enter MCGUI on the >command line, the GUI screen appears for an instant then disappears and the >following message is displayed in the command window. > >MCGUI >Error in startup script: > System Key word 1 read failed (-3) >"mcidas syskey $1" > (procedure "syskeyLoad" line 5) > invoked from within > (file "/unidata/mcidas/bin/mcgui.k" line 1333) This is most likely caused from the user's McIDAS-X session not having a valid REDIRECTion for the copy of SYSKEY.TAB that is located in the directory where AREA, MDXX, and GRID files get decoded. >I was afraid at first that this might have something to do with two users >using the same account on different machines but I am now pretty sure that >was not the case. Are you saying that the same account, with the same HOME directory works differently on two different workstations? From conversations we have had previously, I suspect that the user's HOME directory for a user is local to the machine that they are running on. Is this not the case? If it is the case, I suspect the missing or incorrect REDIRECT for SYSKEY.TAB. >McIDAS seems to work on other respects on this machine. Only the MCGUI and Fkey menus would be affected by this. McIDAS itself should keep running with no problems. >Also is there any way that a product stream could become suspended >spontaneously: > >After last weekend all the AREA files were several days old. A check of >ROUTE LIST showed that they were all suspended. A RELEASE command restored >the data flow. I do not remember ever having issued a SUSPEND command. No, not that I know of. The only way to change routing table entries is to run ROUTE or to overwrite the copy of ROUTE.SYS with a file where the entries were suspended. Hopefully, the read/write permissions on ROUTE.SYS and SYSKEY.TAB are such that only the users in 'mcidas' group can modify them. >Thank you Talk to you later... Tom >From address@hidden Wed Oct 11 13:45:26 2000 >Subject: Re: 20001009: McIDAS: MCGUI fails I finally traced this problem to the lack of a symbolic link in /var in the offending machine. ATM20 is the file server and has /home/data with /mcidas and /xcd. I mount the disk /home on atm20 as /unidata on each student workstation and then have a link /var/data --> /unidata/data so that the redirections /var/data/mcidas and /var/data/xcd will work in mcidas. Somehow that link disappeared or was never there although I thought that MCGUI used to work. Anyway all is well with that machine. We now have 7 student workstation running both Windows and Linux which can run McIDAS. I am still using the model where there is just one copy of the McIDAS binaries on ATM20. So far the class hasn't exercized the system enough to make it break down. Thanks Erick Lorenz, UCDavis