This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.


  • Subject: [NOAAPORT #RBX-213298]: ports
  • Date: Tue, 03 Mar 2015 12:06:44 -0700

Patrick,

My understanding is that you're trying to close as many ports as possible -- 
while leaving port 388 open for incoming TCP connections -- on the NOAAPORT 
ingester box (the one that's connected to the Novra). Please tell me if this is 
incorrect.

As long as port 388 on the NOAAPORT ingester box is open for incoming TCP 
connctions, then an LDM on a downstream computer shouldn't have problems 
connecting to it *providing* an appropriate ALLOW entry exists in the LDM 
configuration-file on the NOAAPORT ingester box and there are no other 
firewalls between the downstream LDM and the NOAAPORT ingester box.

> Steve,
> 
> I’m talking about the noaaport ingestor box itself.. connected directly to 
> the novra.

Regards,
Steve Emmerson