This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Daniel, > has the ability to have multiple primary feeders for a data source been > removed? the "PRIMARY" keyword at the end of a request line is no > longer supported. Support for the "PRIMARY" and "ALTERNATE" (or is it "SECONDARY") keywords has been removed. If you want two upstream LDM-s to send the same data in PRIMARY mode, then simply enclose the regular-expression in *one* of the REQUEST entries in parentheses. The LDM will then figure that the two REQUESTS are unique and make both connections in PRIMARY mode. > We are trying to mux 2 Level2 radar data provider in a single queue and > let LDM sort out the duplicates. Basicaly we want to eliminate missing > chunk issues that could arise for the primary feeder going down. > > Thanks ! > > -- > Daniel Bourque > Sr. Systems Engineer > AccuWeather > > Office (316) 266-8013 > Office (316) 266-8000 ext. 8013 > Mobile (316) 640-1024 Regards, Steve Emmerson Ticket Details =================== Ticket ID: VGF-661164 Department: Support LDM Priority: Normal Status: Closed