This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.
Karen, Would you please send me an LDM product-identifier that exemplifies the data that Dontpanic wasn't receiving from Pluto. I've diagnosed the discrepancy between an "ldmadmin watch" and a notifyme(1) on Pluto. There isn't a problem: the notifyme(1) process times-out after 5 minutes, disconnects, and then reconnects asking for data that were created on or after the current time. The missing data-products turn out to have been created before that "from" time even though they were delivered later. The "-T totalTimeout" option of notifyme(1) can be used to mitigate this behavior, somewhat. Regards, Steve Emmerson Ticket Details =================== Ticket ID: UAK-912261 Department: Support LDM Priority: Normal Status: On Hold