This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.


  • Subject: [LDM #LJY-425624]: NEXRAD Level II Feed
  • Date: Tue, 03 Jun 2008 16:19:37 -0600

Alan,

The script gtsnp_nr2decomp(1) appears to trigger a compression
of all the decompressed segments of a sweep upon seeing the "/E"
suffix in the product-identifier.  If there's more than a single
path by which data-products from a radar site can arrive at your
LDM, then it's possible that the "/E" data-product will arrive
*not* after the other three data-products of the same sweep have
arrived.  I suspect that the output of the compression utility,
gtsnp_nr2comp(1), will be smaller in this case than if all four
data-products of the sweep had been used.

Regards,
Steve Emmerson