This archive contains answers to questions sent to Unidata support through mid-2025. Note that the archive is no longer being updated. We provide the archive for reference; many of the answers presented here remain technically correct, even if somewhat outdated. For the most up-to-date information on the use of NSF Unidata software and data services, please consult the Software Documentation first.



Thom,

We've never conducted rigorous experiments on the degree of
clock accuracy necessary.  I can tell you from experience,
however, that if your clock is accurate to the nearest tenth
of a second and is monotonic (i.e., doesn't jump backwards
in time) then you won't have any time-related problems.  
Both of these requirements are easily obtained by running
an NTP daemon (e.g., ntpd) that continuously adjusts the
clock slew rate.  Stratum 1 servers would be fine.

Regards,
Steve Emmerson